The store will not work correctly in the case when cookies are disabled.
JavaScript seems to be disabled in your browser.
For the best experience on our site, be sure to turn on Javascript in your browser.
74506
The Loose Tube Cable (LTC) is a non-metallic, loose tube outdoor duct cable, longitudinal water-protected. Installation: by blowing or pulling, into conduits or on cable trays.
LTC 36x SM G.657.A1 (6x6)
For current stock information you need to login. New to TKF Telecom? Please register here
Pdf
Specifications
Cable type
LTC
Fibre type
Single mode 9/125
Optical fibre standard
ITU-T G.657.A1
Number of fibers
36
Number of fibers per optical element
6
Optical element
Loose tube, gel filled
Cable metal free
Yes
Number of layers
1 Layer
Strip method
1 Rip cord
Stripability optical element
> 1000 mm, down to primary coating
Strain relief
Yes
Type of strain relief
FRP
Material outer sheath
PE
Colour outer sheath
Black
Outer sheath thickness
1,5 mm
Outer diameter approx.
9,5 mm
Marking
ACE - TKF LTC 36x SM G.657.A1 (6x6) A-DQ(ZN)2Y 74506 {Batch} {Year} {Length}
Test procedures
EN IEC 60794-1-2
Standardization
EN IEC 60794-3-10
Application
Outside
Blow in
Yes
Euro fire class according to EN 13501-6
Fca
Tensile load short term (Tm)
2000 N
Max. fiber strain at Tm
0,6 %
Tensile load Long Term (Tl)
1500 N
Min. bending radius during installation
200 mm
Min. bending radius after installation
150 mm
Crush resistance E3A short (1min)
2000 N/dm
Impact strength
5 J
Striking surface radius
300 mm
Torsion resistance
360 °/m
Kink resistance
120 mm
Category according to EN 50173
OS2
Max. attenuation @ 1310 nm
0,35 dB/km
Max. attenuation @ 1550 nm
0,22 dB/km
Max. attenuation @ 1625 nm
0,25 dB/km
Longitudinal water blocking
Yes
Longitudinal watertight construction
Super Absorbing Polymer
Installation temperature
-15/55 °C
Transportation and storage temperature
-40/70 °C
Operational temperature range Ta1 - Tb1
-30/70 °C
Max. attenuation increase during Ta1 - Tb1
0,05 dB
Operational temperature range Ta2 - Tb2
-40/70 °C
Max. attenuation increase during Ta2 - Tb2
0,15 dB
TC sample length for TC acc. F1 or F12
1000 m
UV resistant
Yes
UV-protection
ISO 4892/2
Color fastness
Blue wool scale 8
Halogen free (acc. EN 60754-1/2)
Yes
Unit
meter
Netto Weight (kg/m)
0.067
Default packaging
H X 4000/10