77464

The Loose Tube Mini Cable ‘Slim’ (LTMC-S) is a non-metallic, longitudinal water-protected fibre optic cable, with smallest possible outer diameter and optimized fibre density. This cable is perfectly suitable for Access or FTTx applications, where high fibre-count cables in smallest tube-diameter are needed. Installation: blowing into miniducts.
LTMC-S
216x SM G.657.A2 200µm (9x24)

Specifications

Product characteristics
Cable type LTMC
Fibre type Single mode 9/125
Optical fibre standard ITU-T G.657.A2 200 µm
Number of fibers 216
Number of fibers per optical element 24
Optical element Loose tube, gel filled
Cable metal free Yes
Number of layers 1 Layer
Strip method 1 Rip cord
Stripability optical element > 1000 mm, down to primary coating
Strain relief Yes
Type of strain relief FRP
Material outer sheath HDPE
Colour outer sheath Black
Outer sheath thickness 0,4 mm
Outer diameter approx. 7,0 mm
Marking ACE - TKF LTMC-S 216x SM G.657.A2 (9x24) A-DQ(ZN)2Y 77464 {Batch} {Year} {Length}
Application
Test procedures EN IEC 60794-1-2
Standardization EN IEC 60794-5-10
Application Outside
Blow in Yes
Euro fire class according to EN 13501-6 Fca
Mechanical specification
Tensile load short term (Tm) 4000 N
Max. cable strain at Tm 0,8 %
Max. fiber strain at Tm 0,33 %
Tensile load Long Term (Tl) 750 N
Max. fiber strain at Tl 0,0 %
Min. bending radius during installation 140 mm
Min. bending radius after installation 105 mm
Crush resistance E3A short (1min) 3000 N/dm
Crush resistance E3A long 1000 N/dm
Crush load E3A long application time 10 min
Impact strength 4 J
Striking surface radius 300 mm
Torsion resistance 360 °/m
Optical specification
Category according to EN 50173 OS2
Max. attenuation @ 1310 nm 0,35 dB/km
Max. attenuation @ 1550 nm 0,22 dB/km
Max. attenuation @ 1625 nm 0,25 dB/km
Environmental specification
Longitudinal water blocking Yes
Longitudinal watertight construction Super Absorbing Polymer
Installation temperature -15/50 °C
Transportation and storage temperature -45/70 °C
Operational temperature range Ta1 - Tb1 -30/70 °C
Max. attenuation increase during Ta1 - Tb1 0,05 dB
Operational temperature range Ta2 - Tb2 -40/70 °C
Max. attenuation increase during Ta2 - Tb2 0,15 dB
TC sample length for TC acc. F1 or F12 1000 m
UV resistant Yes
Other specification
Halogen free (acc. EN 60754-1/2) Yes
Logistical specifications
Unit meter
Netto Weight (kg/m) 0.048