The store will not work correctly in the case when cookies are disabled.
77419
Stock
For current stock information you need to login. New to TKF Telecom? Please register here
Pdf
Specifications
|
|
Cable type |
LTMC |
Fibre type |
Single mode 9/125 |
Optical fibre standard |
ITU-T G.657.A1 |
Number of fibers |
288 |
Number of fibers per optical element |
12 |
Optical element |
Loose tube, gel filled |
Cable metal free |
Yes |
Number of layers |
2 Layers |
Strip method |
1 Rip cord |
Stripability optical element |
> 1000 mm, down to primary coating |
Strain relief |
Yes |
Type of strain relief |
FRP |
Material outer sheath |
HDPE |
Colour outer sheath |
Black |
Outer sheath thickness |
0,45 mm |
Outer diameter approx. |
9,5 mm |
Marking |
ACE - TKF LTMC-S 288x SM G.657.A1 ((9+15)x12) A-DQ(ZN)2Y 77419 {Batch} {Year} {Length} |
Test procedures |
EN IEC 60794-1-2 |
Standardization |
EN IEC 60794-5-10 |
Application |
Outside |
Blow in |
Yes |
Euro fire class according to EN 13501-6 |
Fca |
Tensile load short term (Tm) |
3000 N |
Max. cable strain at Tm |
0,65 % |
Max. fiber strain at Tm |
0,4 % |
Tensile load Long Term (Tl) |
500 N |
Max. fiber strain at Tl |
0,0 % |
Min. bending radius during installation |
190 mm |
Min. bending radius after installation |
140 mm |
Crush resistance E3A short (1min) |
1200 N/dm |
Crush resistance E3A long |
600 N/dm |
Crush load E3A long application time |
10 min |
Impact strength |
8 J |
Striking surface radius |
300 mm |
Torsion resistance |
360 °/m |
Category according to EN 50173 |
OS2 |
Max. attenuation @ 1310 nm |
0,35 dB/km |
Max. attenuation @ 1550 nm |
0,22 dB/km |
Max. attenuation @ 1625 nm |
0,25 dB/km |
Longitudinal water blocking |
Yes |
Longitudinal watertight construction |
Super Absorbing Polymer |
Installation temperature |
-15/50 °C |
Transportation and storage temperature |
-45/70 °C |
Operational temperature range Ta1 - Tb1 |
-40/70 °C |
Max. attenuation increase during Ta1 - Tb1 |
0,05 dB |
Operational temperature range Ta2 - Tb2 |
-40/70 °C |
Max. attenuation increase during Ta2 - Tb2 |
0,15 dB |
TC sample length for TC acc. F1 or F12 |
1000 m |
UV resistant |
Yes |
Halogen free (acc. EN 60754-1/2) |
Yes |
Unit |
meter |
Netto Weight (kg/m) |
0.079 |
Default packaging |
H X 12000/600 |