77430

The Loose Tube Mini Cable ‘Slim’ Polyamide (LTMC-S PA) is a non-metallic, longitudinal water-protected fibre optic cable, with smallest possible outer diameter and optimized fibre density (in case of applying 200µm fibres). With its low weight and reduced diameter, in combination with a low friction polyamide outer-sheath, this cable is the perfect solution for situations where blowing of mini-cable over long distances in shortest possible time slot is needed. This cable is extremely suitable for Access or FTTx applications, where high fibre-count cables in smallest tube-diameter are required. Installation: blowing into mini-ducts.
LTMC-S PA
48x SM G.657.A2 200µm (4x12)

Specifications

Product characteristics
Cable type LTMC
Fibre type Single mode 9/125
Optical fibre standard ITU-T G.657.A2 200 µm
Number of fibers 48
Number of fibers per optical element 12
Optical element Loose tube, gel filled
Cable metal free Yes
Number of layers 1 Layer
Strip method 1 Rip cord
Strain relief Yes
Type of strain relief FRP
Material outer sheath Polyamide
Colour outer sheath Orange
Outer sheath thickness 0,35 mm
Outer diameter approx. 4,4 mm
Marking ACE - TKF LTMC-S PA 48x SM G.657.A2 (4x12) A-DQ(ZN)4Y 77430 {Batch} {Year} {Length}
Application
Test procedures EN IEC 60794-1-2
Standardization EN IEC 60794-5-10
Application Outside
Blow in Yes
Euro fire class according to EN 13501-6 Fca
Mechanical specification
Tensile load short term (Tm) 800 N
Max. cable strain at Tm 0,7 %
Max. fiber strain at Tm 0,5 %
Tensile load Long Term (Tl) 150 N
Max. fiber strain at Tl 0,0 %
Min. bending radius during installation 90 mm
Min. bending radius after installation 65 mm
Crush resistance E3A short (1min) 1200 N/dm
Crush resistance E3A long 500 N/dm
Crush load E3A long application time 10 min
Impact strength 2,5 J
Striking surface radius 300 mm
Torsion resistance 360 °/m
Optical specification
Category according to EN 50173 OS2
Max. attenuation @ 1310 nm 0,35 dB/km
Max. attenuation @ 1550 nm 0,22 dB/km
Max. attenuation @ 1625 nm 0,25 dB/km
Environmental specification
Longitudinal water blocking Yes
Longitudinal watertight construction Super Absorbing Polymer
Installation temperature -15/55 °C
Transportation and storage temperature -45/70 °C
Operational temperature range Ta1 - Tb1 -30/70 °C
Max. attenuation increase during Ta1 - Tb1 0,05 dB
Operational temperature range Ta2 - Tb2 -30/70 °C
Max. attenuation increase during Ta2 - Tb2 0,15 dB
TC sample length for TC acc. F1 or F12 1000 m
UV-protection ISO 4892/2
Color fastness Blue wool scale 8
With rodent protection Yes
Termite protected Yes
Other specification
Halogen free (acc. EN 60754-1/2) Yes
Logistical specifications
Unit meter
Netto Weight (kg/m) 0.016
Default packaging H X 12000/600